select.parts
Full list

Neousys systems listing EN 50155 for a rolling-stock project

Asked as: “Rolling-stock project. Which Neousys systems list EN 50155?”

Answered by the Rapidflare agent

Five Neousys systems list EN 50155. Each one gives it as "EN 50155:2017, Clause 13.4.8", and all five also list EN 50121-3.

Neousys systems that list EN 50155 neousys-te... +4neousys-tech.com ↗“EN 50121-3, EN 50155:2017, Clause 13.4.8, mechanical.weight_g=1400 g”neousys-tech.com ↗“EN 50121-3, EN 50155:2017, Clause 13.4.8, mechanical.weight_g=3000”neousys-tech.com ↗“EN 50121-3, EN 50155:2017, Clause 13.4.8, mechanical.weight_g=3800 g”neousys-tech.com ↗“EN 50121-3, EN 50155:2017, Clause 13.4.8, mechanical.weight_g=2600 g, mechanical.shock_rating=MIL-STD-810H”neousys-tech.com ↗“IEC61373:2010, Category 1, Class B Body Mounted (EN 50155)”

ProductCatalog groupJetson module familyOther shock/vibration standards listedOperating temp
NRU-52S+ / NRU-52SEmbedded AI SystemsOrin NX, Orin Nano, Xavier NXMIL-STD-810H-25 to 70 °C
NRU-162S-AWPEmbedded AI SystemsOrin NX, Orin NanoMIL-STD-810H; IP66-25 to 70 °C
NRU-172S-PPCEmbedded AI SystemsOrin NX, Orin NanoMIL-STD-810H; IP66-25 to 60 °C
NRU-220SNVR / Video Analytics SystemsAGX Orin, AGX Orin IndustrialMIL-STD-810H-25 to 70 °C
NRU-222SNVR / Video Analytics SystemsAGX Orin, AGX Orin IndustrialIEC 61373:2010, Category 1, Class B Body Mounted (EN 50155)-40 to 75 °C

How these compare:

  • NRU-222S has the widest operating temperature range of the five. It's also the only one whose shock and vibration ratings are listed against IEC 61373 rather than MIL-STD-810H. neousys-te...neousys-tech.com ↗“thermal.max_operating_temp_c=75 °C, thermal.min_operating_temp_c=-40 °C”
  • Performance: the AGX Orin systems (NRU-220S and NRU-222S) list 275 TOPS, and the three Orin NX/Nano systems list 100 TOPS. Both figures are INT8, sparse. neousys-te... +2neousys-tech.com ↗“performance.max_ai_tops=275 TOPS”neousys-tech.com ↗“INT8 TOPS (sparse)”neousys-tech.com ↗“performance.max_ai_tops=100 TOPS, performance.ai_perf_basis=INT8 TOPS (sparse, Base)”
  • Temperature conditions: each range depends on the power mode and installed peripherals. For the NRU-52S, it also depends on PoE load. neousys-te... +1neousys-tech.com ↗“operating_temp_condition=Depends on power mode, Depends on PoE load”neousys-tech.com ↗“thermal.operating_temp_condition=Depends on power mode, Depends on SKU or module, Depends on installed peripherals”

Things to check before you commit:

  • Which clause is listed: EN 50155 is always given together with "Clause 13.4.8". Please confirm with Neousys whether that means full EN 50155 compliance or only that clause.
  • Similar models without EN 50155: several Neousys systems tagged for railway list only CE, FCC Class A, EN 55032/55035 and MIL-STD-810H, with no EN 50155. These are the NRU-51V, NRU-161V-AWP, NRU-171V-PPC, NRU-230V-AWP and NRU-240S-AWP. Make sure the exact SKU you order is one from the table above. neousys-te... +1neousys-tech.com ↗“EN 55035, MIL-STD-810H, mechanical.weight_g=1400 g”neousys-tech.com ↗“application.application_domains=surveillance_nvr, railway”

Sources

  1. NRU-52S+ / NRU-52S neousys-tech.com
  2. NRU-162S-AWP neousys-tech.com
  3. NRU-172S-PPC neousys-tech.com
  4. NRU-220S neousys-tech.com
  5. NRU-51V+ / NRU-51V neousys-tech.com
  6. NRU-240S-AWP neousys-tech.com