Five Neousys systems list EN 50155. Each one gives it as "EN 50155:2017, Clause 13.4.8", and all five also list EN 50121-3.
Neousys systems that list EN 50155 neousys-te... +4neousys-tech.com ↗“EN 50121-3, EN 50155:2017, Clause 13.4.8, mechanical.weight_g=1400 g”neousys-tech.com ↗“EN 50121-3, EN 50155:2017, Clause 13.4.8, mechanical.weight_g=3000”neousys-tech.com ↗“EN 50121-3, EN 50155:2017, Clause 13.4.8, mechanical.weight_g=3800 g”neousys-tech.com ↗“EN 50121-3, EN 50155:2017, Clause 13.4.8, mechanical.weight_g=2600 g, mechanical.shock_rating=MIL-STD-810H”neousys-tech.com ↗“IEC61373:2010, Category 1, Class B Body Mounted (EN 50155)”
| Product | Catalog group | Jetson module family | Other shock/vibration standards listed | Operating temp |
|---|---|---|---|---|
| NRU-52S+ / NRU-52S | Embedded AI Systems | Orin NX, Orin Nano, Xavier NX | MIL-STD-810H | -25 to 70 °C |
| NRU-162S-AWP | Embedded AI Systems | Orin NX, Orin Nano | MIL-STD-810H; IP66 | -25 to 70 °C |
| NRU-172S-PPC | Embedded AI Systems | Orin NX, Orin Nano | MIL-STD-810H; IP66 | -25 to 60 °C |
| NRU-220S | NVR / Video Analytics Systems | AGX Orin, AGX Orin Industrial | MIL-STD-810H | -25 to 70 °C |
| NRU-222S | NVR / Video Analytics Systems | AGX Orin, AGX Orin Industrial | IEC 61373:2010, Category 1, Class B Body Mounted (EN 50155) | -40 to 75 °C |
How these compare:
- NRU-222S has the widest operating temperature range of the five. It's also the only one whose shock and vibration ratings are listed against IEC 61373 rather than MIL-STD-810H. neousys-te...neousys-tech.com ↗“thermal.max_operating_temp_c=75 °C, thermal.min_operating_temp_c=-40 °C”
- Performance: the AGX Orin systems (NRU-220S and NRU-222S) list 275 TOPS, and the three Orin NX/Nano systems list 100 TOPS. Both figures are INT8, sparse. neousys-te... +2neousys-tech.com ↗“performance.max_ai_tops=275 TOPS”neousys-tech.com ↗“INT8 TOPS (sparse)”neousys-tech.com ↗“performance.max_ai_tops=100 TOPS, performance.ai_perf_basis=INT8 TOPS (sparse, Base)”
- Temperature conditions: each range depends on the power mode and installed peripherals. For the NRU-52S, it also depends on PoE load. neousys-te... +1neousys-tech.com ↗“operating_temp_condition=Depends on power mode, Depends on PoE load”neousys-tech.com ↗“thermal.operating_temp_condition=Depends on power mode, Depends on SKU or module, Depends on installed peripherals”
Things to check before you commit:
- Which clause is listed: EN 50155 is always given together with "Clause 13.4.8". Please confirm with Neousys whether that means full EN 50155 compliance or only that clause.
- Similar models without EN 50155: several Neousys systems tagged for railway list only CE, FCC Class A, EN 55032/55035 and MIL-STD-810H, with no EN 50155. These are the NRU-51V, NRU-161V-AWP, NRU-171V-PPC, NRU-230V-AWP and NRU-240S-AWP. Make sure the exact SKU you order is one from the table above. neousys-te... +1neousys-tech.com ↗“EN 55035, MIL-STD-810H, mechanical.weight_g=1400 g”neousys-tech.com ↗“application.application_domains=surveillance_nvr, railway”