I searched our catalog for Xavier NX-based Edge AI Box PCs (Lanner excluded) rated to -30 °C or colder. Six models qualify — two from NEXCOM and four from Axiomtek. All of them are rated to exactly -30 °C minimum operating temperature; no other vendor's Xavier NX box PC in the catalog goes colder than that.
| Vendor | Model | Min op. temp | Max op. temp | IP rating | Notes |
|---|---|---|---|---|---|
| NEXCOM | ATC 3530-IP7-4C | -30 °C | 70 °C | IP67 | 5x GbE (4x PoE), 1x CAN, 5G |
| NEXCOM | ATC 3530-IP7-4M | -30 °C | 70 °C | IP67 | 2x GbE, 1x CAN, 5G, 4x MIPI camera inputs |
| Axiomtek | AIE900-XNX | -30 °C | 60 °C | IP40 | 5x GbE (4x PoE), 2x COM/CAN, 5G option |
| Axiomtek | AIE100-903-FL-NX | -30 °C | 50 °C | IP40 | Compact (900 g), 2x GbE (1x PoE), 4G/LTE |
| Axiomtek | AIE800-904-FL | -30 °C | 50 °C | IP67 | 1x M12 GbE PoE (802.3at), 100–240 VAC input |
| Axiomtek | AIE800-904-FL-DC | -30 °C | 50 °C | IP67 | 1x M12 GbE PoE (802.3af), 9–36 VDC input |
nexcom.com... +5nexcom.com.tw ↗“thermal.min_operating_temp_c=-30 °C”nexcom.com ↗“thermal.min_operating_temp_c=-30 °C”axiomtek.com.tw ↗“thermal.min_operating_temp_c=-30 °C”axiomtek.com ↗“thermal.min_operating_temp_c=-30 °C”axiomtek.com ↗“thermal.min_operating_temp_c=-30 °C”axiomtek.com ↗“thermal.min_operating_temp_c=-30 °C”
A few points worth noting:
- All six are fanless and rated at 21 TOPS (dense INT8), the standard Xavier NX figure. nexcom.com... +1nexcom.com.tw ↗“21 INT8 TOPS (dense)”axiomtek.com.tw ↗“thermal.cooling=Fanless”
- Nothing goes below -30 °C. If you truly need -40 °C-class operation like the Lanner EAI-I130A/B, no other vendor's Xavier NX box PC in our catalog is rated that cold — the two NEXCOM ATC 3530 models (IP67, fanless, telematics/railway oriented, -30 to 70 °C) are the closest match to the Lanner unit's wide-range profile. nexcom.com... +1nexcom.com.tw ↗“application.application_domains=in_vehicle_telematics, railway”nexcom.com.tw ↗“thermal.max_operating_temp_c=70 °C”
- The NEXCOM units' temperature range holds only under their stated conditions — it depends on power mode, and on the -4C variant also on PoE load — so verify against your deployment before committing. nexcom.com... +1nexcom.com.tw ↗“Depends on power mode, Depends on PoE load”nexcom.com ↗“Depends on power mode”