select.parts
Cross-reference

Other vendors' Xavier NX box PCs rated to -30°C or colder

Asked as: “The Lanner EAI-I130A/B runs a Xavier NX down to -40°C. Which other vendors' Xavier NX box PCs are rated to -30°C or colder?”

Answered by the Rapidflare agent

I searched our catalog for Xavier NX-based Edge AI Box PCs (Lanner excluded) rated to -30 °C or colder. Six models qualify — two from NEXCOM and four from Axiomtek. All of them are rated to exactly -30 °C minimum operating temperature; no other vendor's Xavier NX box PC in the catalog goes colder than that.

VendorModelMin op. tempMax op. tempIP ratingNotes
NEXCOMATC 3530-IP7-4C-30 °C70 °CIP675x GbE (4x PoE), 1x CAN, 5G
NEXCOMATC 3530-IP7-4M-30 °C70 °CIP672x GbE, 1x CAN, 5G, 4x MIPI camera inputs
AxiomtekAIE900-XNX-30 °C60 °CIP405x GbE (4x PoE), 2x COM/CAN, 5G option
AxiomtekAIE100-903-FL-NX-30 °C50 °CIP40Compact (900 g), 2x GbE (1x PoE), 4G/LTE
AxiomtekAIE800-904-FL-30 °C50 °CIP671x M12 GbE PoE (802.3at), 100–240 VAC input
AxiomtekAIE800-904-FL-DC-30 °C50 °CIP671x M12 GbE PoE (802.3af), 9–36 VDC input

nexcom.com... +5nexcom.com.tw ↗“thermal.min_operating_temp_c=-30 °C”nexcom.com ↗“thermal.min_operating_temp_c=-30 °C”axiomtek.com.tw ↗“thermal.min_operating_temp_c=-30 °C”axiomtek.com ↗“thermal.min_operating_temp_c=-30 °C”axiomtek.com ↗“thermal.min_operating_temp_c=-30 °C”axiomtek.com ↗“thermal.min_operating_temp_c=-30 °C”

A few points worth noting:

  • All six are fanless and rated at 21 TOPS (dense INT8), the standard Xavier NX figure. nexcom.com... +1nexcom.com.tw ↗“21 INT8 TOPS (dense)”axiomtek.com.tw ↗“thermal.cooling=Fanless”
  • Nothing goes below -30 °C. If you truly need -40 °C-class operation like the Lanner EAI-I130A/B, no other vendor's Xavier NX box PC in our catalog is rated that cold — the two NEXCOM ATC 3530 models (IP67, fanless, telematics/railway oriented, -30 to 70 °C) are the closest match to the Lanner unit's wide-range profile. nexcom.com... +1nexcom.com.tw ↗“application.application_domains=in_vehicle_telematics, railway”nexcom.com.tw ↗“thermal.max_operating_temp_c=70 °C”
  • The NEXCOM units' temperature range holds only under their stated conditions — it depends on power mode, and on the -4C variant also on PoE load — so verify against your deployment before committing. nexcom.com... +1nexcom.com.tw ↗“Depends on power mode, Depends on PoE load”nexcom.com ↗“Depends on power mode”

Sources

  1. ATC 3530-IP7-4C nexcom.com.tw
  2. ATC 3530-IP7-4M nexcom.com
  3. axiomtek.com.tw axiomtek.com.tw
  4. axiomtek.com axiomtek.com
  5. AIE800-904-FL axiomtek.com
  6. AIE800-904-FL-DC axiomtek.com
  7. AIE900-XNX axiomtek.com.tw
  8. AIE100-903-FL-NX axiomtek.com