Six partner products that support the Jetson AGX Xavier Industrial module family are rated down to −40 °C. Note that none of these is the first-party NVIDIA module itself — among NVIDIA's own Jetson modules, I found no entry matching the AGX Xavier family with a minimum operating temperature at or below −40 °C. Here are the partner systems and boards that do meet it:

ProductManufacturerCatalog GroupRated Temp RangeCooling
IPC/RSLA3SyslogicEdge AI Box PCs−40 to 70 °CFanless
IPC/RSLA3 (Railway)SyslogicEdge AI Box PCs−40 to 70 °CFanless
RTSS-X102TRealtimesEmbedded AI Systems−40 to 55 °CFanless
RTSO-1001RealtimesCarrier Boards−40 to 85 °CFan/Fanless
MILBOARD-AGXForecrCarrier Boards−40 to 85 °CFan/Fanless
VPX3U-XAVIER-CX6-HPC (WOLF-12TZ)WOLF Advanced TechnologyModular Compute Boards / Blades−40 to 85 °CConduction

syslogic.com +5syslogic.com ↗“thermal.min_operating_temp_c=-40 °C, identity.manufacturer=Syslogic”syslogic.com ↗“thermal.min_operating_temp_c=-40 °C, identity.manufacturer=Syslogic”realtimesai.com ↗“thermal.min_operating_temp_c=-40 °C, thermal.max_operating_temp_c=55 °C”realtimesai.com ↗“thermal.min_operating_temp_c=-40 °C, thermal.cooling=Fan/Fanless”forecr.io ↗“thermal.min_operating_temp_c=-40 °C, identity.manufacturer=Forecr”wolfadvancedtechnology.com ↗“thermal.min_operating_temp_c=-40 °C, thermal.cooling=Conduction”

A few notes on specific models:

  • The Syslogic IPC/RSLA3 pair are full systems for Jetson AGX Xavier/AGX Xavier Industrial, rated −40 to 70 °C; the Railway variant carries EN50155, EN45545 HL3, and EN61373 shock/vibration certifications for rail deployments, while the standard RML A3 unit targets rugged/military applications — both with 4G/LTE, GNSS/GPS, and Wi-Fi/BT connectivity. syslogic.com +1syslogic.com ↗“EN50155, EN45545 HL3”syslogic.com ↗“application.application_domains=rugged_military”
  • The RTSS-X102T full system's temperature range depends on SKU or installed module, so confirm the exact variant before deploying at the cold end. realtimesa...realtimesai.com ↗“Depends on SKU or module”
  • The WOLF VPX3U-XAVIER-CX6-HPC (WOLF-12TZ) is a 3U OpenVPX conduction-cooled module combining the AGX Xavier Industrial with a CX6 GPU, MIL-STD-810 and MIL-STD-461 certified, SOSA-aligned — the most defense-oriented of the group. wolfadvanc...wolfadvancedtechnology.com ↗“MIL-STD-810, MIL-STD-461, SOSA-aligned”
  • The Realtimes RTSO-1001 and Forecr MILBOARD-AGX are carrier boards (you supply the module), both rated to 85 °C at the top end. realtimesa... +1realtimesai.com ↗“identity.hardware_type=Carrier Board, thermal.max_operating_temp_c=85 °C”forecr.io ↗“identity.hardware_type=Carrier Board”

Sources

  1. IPC/RSLA3 syslogic.com
  2. IPC/RSLA3 (Railway) syslogic.com
  3. RTSS-X102T realtimesai.com
  4. RTSO-1001 realtimesai.com
  5. MILBOARD-AGX forecr.io
  6. VPX3U-XAVIER-CX6-HPC (WOLF-12TZ) wolfadvancedtechnology.com